Key Features
  • Sold & Supported in North America by: LaserDiodeSource.com, part of the Laser Lab Source Marketplace Group
  • 594 nm Laser System with up to 100 mW User Adjustable Output Power
  • Free-Space Output With Shutter
  • High Stability, Excellent Circular Beam Quality, Low Noise Output
  • Manufactured by Coherent, a Laser Lab Source Marketplace Seller; Mfr sku 1285744

Price and Delivery Quote

Buy Now / Add to Cart

Technical Questions for this Product

ASK AN ENGINEER

Customers Also Considered:

Why do Scientists & Engineers Choose Laser Lab Source?

MODEL 1285744 / 594NM-OBIS-LASER
PRICE $11795.00
Output Specifications
  • Wavelength: 594 nm (± 2 nm)
  • Wavelength Color: Orange
  • Output Power: 100 mW, User Adjustable
  • Technology: Optically Pumped Semiconductor Laser
  • Warm-Up Time: 5 min
  • Laser Drive Modes: CW, Analog Modulation, Digital Modulation and Computer Control
  • Output Powers Available: 20mW, 60mW, 100mW
Optical Beam and Output Specifications
  • M2 Beam Quality: ≤ 1.1 (beam quality measured @ full 90/10 clip levels)
  • Beam Asymmetry: ≤ 1:1.1
  • Spatial Mode: TEM00
  • Beam Type / Shape: Circular Beam
  • Beam Diameter at 1/e²: 0.7 ±0.05 mm
  • Beam Divergence (full-angle): < 1.3 mrad
  • Pointing Stability (over 2 hours after warm-up and ±3°C): < 30 μrad
  • Pointing Stability Over Temp.: < 5 μrad/°C
  • RMS Noise, 20 Hz to 20 MHz: ≤ 0.25 %
  • Peak to Peak Noise, 20 Hz to 20 kHz: < 1 %
  • Long Term Power Stability (8 hrs, ±3ºC): < 2 %
  • Polarization Ratio: Minimum 100:1, Vertical ± 5°
  • Warm-Up Time, from Cold Start: < 5 min.
  • Static Alignment Tolerances
  • Beam Position from Reference: < 0.5 mm *
  • Beam Angle: < 2.5 mrad *
  • Beam Waist Position at Exit Window: ±200 mm
  • * See Mechanical Drawing for Beam Exit Location
MODULATION Specifications
  • Digital Modulation
  • Digital Input: SMB, 0 V to 3 V, 50 Ω input impedance
  • Maximum Bandwidth: 0.05 MHz
  • Rise Time (10% to 90%): < 18 µsec
  • Fall Time (90% to 10%): < 2 µsec
  • Modulation Extinction Ratio: Infinite at 0 Hz to 50 kHz
  • Analog Modulation
  • Analog Input: SMB, 0V to 5V, 50 Ω or 2000 Ω input impedance
  • Maximum Bandwidth: 100 kHz
  • Rise Time (10% to 90%): < 3 µsec
  • Fall Time (90% to 10%): < 3 µsec
  • Modulation Extinction Ratio: > 50:1
General Specifications
  • Laser Safety Classification: 3b
  • ESD Protection: EN61326-1
  • Power Consumption: 8 W (typ), 12 W (max)
  • Max Laser Head Baseplate Temperature: 50ºC (LX versions)
  • Max Laser Head Baseplate Temperature: 40ºC (LS versions)
  • Operating Temperature: 15ºC to 40ºC (non condensing)
  • Storage Temperature: -20ºC to 60ºC (non condensing)
UTILITY AND ENVIRONMENTAL REQUIREMENTS
  • Operating Voltage: 12 VDC
  • Safety: Key-Switch and Interlock Connection
  • Laser Head Dimensions: 70 x 40 x 38 mm (2.75 x 1.57 x 1.5 in.)
  • OBIS Remote Dimensions: 105 x 68 x 36 mm (4.13 x 2.68 x 1.42 in.)
  • DC Power Supply Dimensions: 105 x 42 x 33 mm (4.13 x 1.65 x 1.3 in.)
  • Laser Head Weight: 0.16 kg
  • OBIS Remote Weight: 0.23 kg (0.5 lb)
  • DC Power Supply Weight: 0.36 kg (0.79 lbs.)
  • USB Control Interconnection: USB 2.0, Mini-B
  • RS-232 Control Interconnection: RS-232, 11.2 k
  • Remote to Laser Connection: 1 m Cable, included
  • Shock Tolerance (6 msec): 30 g

Product Overview:

594nm, 100mW Ultra-Violet Laser Source System Overview

These plug-and-play laser sources utilize Coherent's Optically Pumped Semiconductor Laser (OPSL) technology to deliver industry-best laser reliability and performance. The OBIS Series laser source systems cover the wavelength spectrum from 375nm (Ultraviolet) to 980nm (near-Infrared), and are perfect for flow cytometry and fluorescence spectroscopy applications.

OBIS LX/LS lasers deliver high optical power with low noise, and high beam quality. The plug-and-play system is flexible, and users are able to rapidly integrate the laser. The result is reduced set-up time and time-to-market in OEM applications, and reduced cost. The highly-functional OBIS LS/LX Systems are ideal for scientific, laboratory, and spectroscopic applications.

Complete Turn-Key Oranger Laser Source System

The complete laser system includes: the laser head and power supply, remote controller, and the interconnect cables. The laser system is operated remotely via USB or RS232, and the PC control software is included.

The laser system includes features to ensure a long operating lifetime, and to help protect the laser operator. The key switch prevents unauthorized use, and the external interlock allows a remote safety switch to be wired. The OBIS remote controller includes a Laser Ready and Laser On indicator, as well as a front panel Fault indicator. Accommodation is provided for driving a cooling fan, and for temperature stabilization the OBIS laser head can be mounted to the OBIS fan-heatsink.

Operating Flexibility with Multiple Modulation Modes

The OBIS laser system can be operated in CW mode, or modulated in multiple modes: analog signals, digital signals, and combined analog/digital signals. The laser can be modulated to full-off output, ensuring no photons are emitted. LS modules can be modulated to full-off output using the digital modulation mode.

Laser System Options and Availability

The turn-key OBIS laser sources are available in a wide range of wavelengths and output powers, either fiber-coupled or with a free-space output, and multiple sources can be simultaneously operated from a single computer. When application requirements change, laser heads of different wavelengths are quickly exchanged on the bench.

A number of bandpass filters are available for the free-space laser heads, and are useful in applications that benefit from reduced noise at longer wavelengths. Filters are available at 445nm, 473nm, 488nm, 633nm, and 640nm, and attach directly to the front of the laser head.

A range of multi-laser accessories are available: two six-laser controller models for OEM and benchtop applications, a machined heatsink with attached cooling fan, and an integrated mounting and control system that incorporates independent laser controllers, modulation inputs, and thermal management for up to five OBIS laser heads.

Why do Scientists & Engineers Choose Laser Lab Source?

  • Get DIRECT, Fast Tech-Support from the Product Engineer, No Sales Person in the Middle

  • Get the Lowest Price, Factory Direct, No Mark-Up's, Suppliers Post their Own Price

  • Get a 30 Day Evaluation Period with No Risk Return on Most Products, Check Availability