Home  >  Wavelengths 800nm-895nm  >  OsTech   >  LDX-808NM-100W

 

808nm, 100 Watt Turn-Key Laser Diode Source & Control System; User Adjustable Output Power 0-100W

  • 100W Coherent Laser Diode 808nm Front View
  • 100W Coherent Laser Diode 808nm Rear View
  • 100W Coherent Inc Laser Diode 808nm Top View
  • LabView Drivers for Coherent Inc Laser Diode 100W
  • QCW Mode 100W Laser Diode from Coherent Inc

$12485.00   Ships: 6 to 8 wks | Model LDX-808NM-100W

Key Features
  • Includes 100W, 808nm, Coherent / DILAS Fiber Coupled Laser Diode
  • Turn-Key, Fully Configured Control Unit with Integrated Laser Diode Source
  • Factory Set Current & Temperature Limits Keep Laser in Safe Operating Range
  • User Adjustable Laser Output Power 0 to 100 Watts (CW)
  • User Adjustable Laser Temperature within Safe Operating Range
  • CW and QCW Modes
  • RS232 and USB with LabView Drivers
  • Manufactured by OsTech, offered by Laser Lab Source

Price and Delivery Quote

You will receive factory-direct price with no mark-ups

Technical Questions for this Product

ASK AN ENGINEER

Questions route directly to the correct Product Engineer

Why do Scientists & Engineers Choose Laser Lab Source?

  • NO SALES PERSON. Get direct access to the correct product ENGINEER. learn more »

  • NO MARK-UP's. Manufacturer's set their own lowest direct pricing. learn more »

  • LEADING BRANDS. We make it simple to buy from top Global suppliers. learn more »

Customers Also Considered:

MODEL LDX-808NM-100W
PRICE $12485.00
OPTICAL OUTPUT: LASER DIODE SPECIFICATIONS (TYPICAL @ 25°C)
  • Center Wavelength: 808 nm (+/-3 nm)
  • CW Output Power (min): 100 Watts
  • Slope Efficiency: > 1.6 W/A
  • Electrical to Optical Efficiency: > 40 %
  • Spectral width (FWHM): < 4 nm
  • Wavelength Shift with Temperature: 0.27 nm/°C
  • Numerical Aperture: NA 0.22
  • Fiber Core Diameter: 400 µm
  • Fiber Connector: SMA905
  • Red Pilot Laser: Included
CONTROL UNIT CURRENT & VOLTAGE SPECIFICATIONS
  • Laser Diode Bias Current Range: 0.00 - 75.00 Amps
  • Laser Diode Bias Voltage Range: 6.00 Volts
  • Current Noise & Ripple (rms): < 1% full scale
  • Current Setpoint Resolution: 10 mA
  • Current Setpoint Accuracy: +/- 0.5%
  • Current Source Noise & Ripple (rms): < ± 0.5% ( of full scale current )
  • Current Source Set-point Resolution: 25 mA
  • Current Source Setpoint Accuracy: ± 0.5%
  • Current Source Stability (4 hours): ≤ 300 ppm
  • Current Source Limit Setpoint Accuracy: ± 2%
  • Photodiode Current Measurement Accuracy: ± 0.5%
  • Photodiode Current Measurement Range: 0.00 - 4,000 μA
CONTROL UNIT LASER DIODE PROTECTION FEATURES
  • Soft-Start Current Ramp to Setpoint (User Programmable)
  • Soft-Start Current Ramp Factory Default Set to 300 Milliseconds
  • Factory Pre-Set Maximum Current Limit
  • Factory Pre-Set Upper Temperature Limit
  • ESD and Power Surge Clamp
  • Reverse Voltage Transient Clamp
  • AC Line Filter
  • Keylock Switch and Safety Interlock
  • Short Circuit when Laser Diode Current Turned OFF
  • Front Panel e-Stop Button Emergency Shut-Down
  • Factory Pre-Set Upper Temperature Limit
  • Open Circuit Detection and Fast Shut-Down
CONTROL UNIT TEMPERATURE CONTROLLER AND peltier COOLED LASER MOUNTING PLATE SPECIFICATIONS
  • Cooling Method: TEC Cooled Laser Mounting Plate, Water Cooled Base Assembly for Waste Heat Removal
  • Laser Diode Mounting Plate Material: Nickel Plated Copper
  • Laser Diode Mounting Plate Thermal Resistance: < 0.06 K/W
  • TEC Controller Output Power Total: 336 Watts
  • TEC Controller Output Current Range (bipolar): ± 7.00 Amps
  • TEC Controller Output Voltage Range (bipolar) : ± 48.00 Volts
  • Laser Temperature Setpoint: User Adjustable w/in Factory Set Range
  • TEC Control Loop Algorithm: Full P.I.D.
  • P.I.D. Variables: Factory Pre-Set for Optimum Performance
  • Temperature Control Accuracy: 0.05°C
  • TEC Controller Setpoint Resolution: 0.01°C
  • Laser Diode Upper & Lower Temperature Limits: Factory Pre-Set
  • Control Unit Waste Heat Removal Method: Water
  • Required Water Supply Flow Rate: 150 to 200 Liters per Hour
  • Recommended Operating Water Temperature Range: 18 to +23 °C
  • Recommended Water Quality: Max. Particle Size: < 10 μm
  • Water Connectors: 12 mm or 3/4 inch Push Fittings (customer specified)
QCW pulse and MODULATION specifications
  • QCW Mode Rise and Fall Time: < 30 μs, (< 10μs on request)
  • QCW Pulse Trigger: Internal Function Generator or External Trigger
  • QCW Trigger: Internal Function Generator or External Trigger
  • QCW Pulse Modes: Continuous Pulses, Single Pulses, Bursts
  • QCW Pulse Time Base Accuracy: ± 1.0%
  • MODULATION Signal: Accepts External Digital (TTL) or Analog
  • MODULATION Input Connetor: BNC, Input Impedance 10K ohm
  • MODULATION Input Voltage Range: 0 ~ 4 Volts (4V = Max Current)
Fiber Output
  • Fiber Core Diameter: 400 µm
  • Numerical Aperture: 0.22
  • Fiber Connector: SMA905
  • Fiber Patch Cord: Optional (request pricing)
Control Unit / SYSTEM DIMENSIONS AND POWER REQUIREMENT
  • Height: 3U (rack units)
  • Depth: 340 mm
  • Width: 48.26 cm (Standard 19 inch rack width)
  • Input Power: Universal 110V ~230 VAC, 50/60Hz
  • Rack Mount Brackets: Included
  • Bench-top Folding Feet: Included
USER INTERFACE
  • Front Panel LCD, Full Alphanumeric Display with Key Pad
  • RS232 Standard
  • USB Optional ($100.00)
  • LabView Drivers Included
  • GUI Control Software Included

Product Overview:

The model LDX-808NM-100W source and control systems are high performance, pre-configured laser diode systems designed for R&D lab and manufacturing applications. An integrated 100 Watt, 808 nm DILAS fiber coupled source is precisely controlled to provide a high stability output.

The LDX-808NM-100W systems include a Coherent Laser, Inc. (formerly DILAS) high power fiber coupled source, a precision high power laser diode current source, a 336 watt Peltier - TEC temperature controller and a water cooled base laser mounting plate. All of these components are integrated into a 3U high, 19 inch wide rack-mount enclosure.

Protection Features Optimized for High Power Laser Diodes:
These source and control systems are built with protection features designed specifically for high power lasers. They are pre-configured with a 300 millisecond soft-start current ramp from 0 to the desired laser output power set point. Additionally, the user can set any ramp time period from 300 msec up to 10 seconds. These protection circuits are optimized for lasers with optical output power levels from 50 Watts to 300 Watts. Other protection features include a factory set upper temperature limit and a maximum current and voltage limit. All limits are set to the DILAS safe operating rang specifications. The LDX series systems have integrated AC power surge clamp circuits to prevent any possible damage from short power brown-outs or black-outs, as well as any potential for ESD surges. They also have an open circuit detector and redundant temperature sensors to protect the laser from thermal damage.

Flexible User Controls:
Users have full control of the DILAS laser through a touch-key front panel menu and LCD display or through the rear-panel digital interface. Laser output power can be adjusted in the optical domain (W) if the user chooses the automatic power (APC) control mode, or by adjusting the current level (ACC mode). The user also has control over the laser temperature set-point within the safe operating range. The LDX system can be controlled remotely by RS232 or by USB. They ship with LabView drivers. Sequencing software is also available for pre-programming multi-step tests.

QCW, Modulation, Internal Function Generator:
In addition to CW mode, the LDX series offer QCW and modulation modes. The control unit ships with an internal function generator which can be used to set the quasi-CW pulses. Also, the user can use an external source to trigger QCW pulses. The control unit will accept either TTL or analog modulation.

Primary Applications:
The high power 100W LDX model systems are used in plastic welding, soldering, illumination, selective laser melting, heat treatment, medical and many materials processing applications.

Why do Scientists & Engineers Choose Laser Lab Source?

  • Get DIRECT, Fast Tech-Support from the Product Engineer, No Sales Person in the Middle

  • Get the Lowest Price, Factory Direct, No Mark-Up's, Suppliers Post their Own Price

  • Get a 30 Day Evaluation Period with No Risk Return on Most Products, Check Availability